Title: Data from Study: Respiratory Motion Correction of PET using MR-Constrained PET-PET Registration
Type Dataset Balfour, Daniel (2015): Data from Study: Respiratory Motion Correction of PET using MR-Constrained PET-PET Registration. Zenodo. Dataset. https://zenodo.org/record/30516
Links
- Item record in Zenodo
- Digital object URL
Summary
This dataset contains the data used to arrive at the conclusions in the research article Respiratory Motion Correction of PET using MR-Constrained PET-PET Registration, by Balfour et al [BioMedical Engineering OnLine 2015, 14:85].
This study was based upon motion-affected PET images simulated from real dynamic MR image volumes, simulated and reconstructed using the Software for Tomographic Image Reconstruction ("STIR", see http://stir.sourceforge.net/). This dataset includes data from MR scans of 4 healthy volunteers (male, aged 22-33).
Three types of data are provided, which should be sufficient for repeating the findings of the study:
Reconstructed PET image volumes, split into 6 respiratory bins ("gates") for each simulation The dynamic 3D MR volumes used to derive the respiratory motion of each volunteer Text files outline which dynamics have NOT been used for PET simulation - these are the ones used to make the motion model in the studyThese MR volumes were registered and combined with the head-foot position of the right hemidiaphragm to form a respiratory motion model, which was subsequently used to constrain PET to PET image registration, attempting to correct for the motion in the PET images.
For more detailed information regarding the method, please refer to the article.
The PET data is split into several sub-categories:
Volunteer ID (4 possibilities, anonymised) Lesion position (9 possibilities - see article for locations) Lesion diameter, in millimetres (10 or 14 mm) Respiratory gate number, ranging from 1 (most inhaled) to 6 (most exhaled)Note that there are two types of each simulation: with motion, and without motion. These are included in the respective zip files for each volunteer ID.
More information
- DOI: 10.5281/zenodo.30516
Subjects
- Positron Emission Tomography, Motion Modelling
Dates
- Publication date: 2015
- Issued: September 04, 2015
Notes
Other: The file names reflect which image the file contains according to a number of substrings. As outlined in the description, there are several tags associated with each PET simulation. Specifically these are: - volnN, where N refers to the volunteer identification number (1-4) - motionless simulations contain the tag "stat", short for "static" - LesPosN, where N refers to the lesion position (1-9) - LesDiamN, where N refers to the lesion diameter in mm (10 or 14) - gateN, where N is the respiratory bin Note that all PET image intensities are multiplied by 100 to avoid problems with numerical precision. All PET filenames contain the substring "x100" to remind the user of this. Each set of PET images are zipped according to volunteer ID and motion status: whether motion is included (substring "wMotion") or not included ("noMotion"). Note that the latter was used for validation purposes. All MR dynamic images are contained within "Dynamics.zip", which follow the tagging system mentioned above - only volunteer ID and the dynamic number are included. Note that there are a total of 35 dynamic volumes for each volunteer, except for volunteer 4, for which there are 70 volumes available. These have been included for completeness.Rights
- https://creativecommons.org/licenses/by/4.0/legalcode Creative Commons Attribution 4.0 International
- info:eu-repo/semantics/openAccess Open Access
Format
electronic resource
Relateditems
Description | Item type | Relationship | Uri |
---|---|---|---|
Cites | https://doi.org/10.1186/s12938-015-0078-5 | ||
IsPartOf | https://zenodo.org/communities/zenodo |